INTools Training. All of these steps can be performed by our customers. However, Fisher recommends that our Representatives be allowed to perform steps 3 through 5.
This will allow our customers to achieve the maximum time and money savings possible. Data files can easily be exchanged via e- mail.
InTools is a set of plug-ins for use with Adobe InDesign. Organize, edit, and share pictures with this free photo mana. Please describe the problem you have with this software. This information will be sent to our. Intergraph is the leading global provider of engineering and geospatial software that enables customers to build and operate more efficient plants and ships, create intelligent maps, and protect critical infrastructure and.
Certain fields must match for INtools to import the data. If you're running the import module successfully, but your actual data sheet in INtools does not reflect the imported data, check the fields below in your import file to make sure that the values are the values that you are expecting. Fisher software exports the values that were originally exported from INtools. If the values in the Fisher export file are not expected values, you may have a problem with INtools exporting blank or erroneous values in the first place. You may manually correct the values on the Fisher export file and then import.
You may also want to contact Intergraph to correct the problems in INtools. You may need to update your version with a service patch from Intergraph. INtools fields that must be present and matching in the Fisher export file in order to import data into INtools: 1.
No specific info about version 7.0. Please visit the main page of SmartPlant Instrumentation on Software Informer. Comments on SmartPlant Instrumentation SI comments. Halo 5's map editor is now available for free in Windows 10. INTools Website. Slide Show. (formely INtools®) software. The information on this page refers to FIRSTVUE but also applies to Fisher's latest control valve sizing program. you are free to read the file in excel. Enterprise Software; Enterprise Components; Products; Customers; Training; Support; TestDrive Center; Webinars; ISO 15926; SmartPlant® Instrumentation Powered by INtools.
Project. Name. 2. Plant. Name. 3. Area. Name. 4. Unit. Number. Project. Unit. 6. Loop. Name. 7. Measured.
Variable. 8. Item. Tag. 9. Instrument. Type. Name. 2. The import module may tell you that "Case ID" or "Case Number" is a problem when running the import. INtools made a change after the Fisher interface was built to accommodate for different process data cases. The import module looks for data to define which "case" you want the data to import to. To work around the issue, open the links for the FIRSTVUE interface in the import module.
The calculation and spec sheet links include fields for "case" in the mapping. Map these to '' (two single quote marks).
This will default the case value and satisfy the import module so that you can import the data. Data imports into the wrong fields in the Fisher program. The interface built into INtools is based upon the use of spec form 7. INtools. This is an ISA spec sheet for control valves.
The user defined fields on the spec form 7. Fisher program. If another spec sheet is used or if spec 7. The export file from the Fisher program may be opened in excel. Please note if excel provides a warning that reads "File not loaded completely". This can occur if more that 2. If you get this warning, you are free to read the file in excel, but saving in excel will result in loosing fields that were beyond the 2.
Note that you can use notepad or other text editing files to edit and save also. INtools has a utility that allows you to rename the units of measure when you export or import data. This mapping has already been done for the FIRSTVUE interface with spec 7. FIRSTVUE link (ie, a custom link to interface with a different spec form). Failure to use this renaming utlity when using a link other than the FIRSTVUE link will result in a failed import when the data is imported into FIRSTVUE because FIRSTVUE will not understand the INtools units of measure.
The utility is located in the import module. In order to access this, select the import link (ie, a custom link created for the project) that you would like to modify the units of measure for.
Now select the system codes selection in the main menu. Now select Adapt UOM codes. This will provide a list of all of the units of measure used in INtools with space to enter the matching FIRSTVUE units. For a complete list of units used in FIRSTVUE, click here.
Process data fields are managed by the process module. This controls the variations of data that are required for gas/vapor vs liquid, for example. Failure to enter process data in the Process Data module will result in the omission of critical fields like compressibility and other fields that are critical to sizing control valves. Be sure to close the csv file from FIRSTVUE prior to importing it into the import module. Failure to do so will result in an error similar to the one below. In this event, simply close the csv file and try again. This error can also be a result of conflicts with the file name (special characters or blanks in the file name or folder) or even if the path to the file name is too long. If your csv file is closed and you get this error, try renaming the file and folders in the path and moving the file to a directory with a shorter path. If the message persists, contact Intergraph support.
Note that multiple Fisher fields can be mapped to import into a single field in INtools. The links in the import module can be written such that more than on Fisher field is mapped to a single INtools field. The import module will concatenate the two Fisher fields and assign the resulting value to the INtools field. Text can also be inserted as needed; for example, Fisher's lower and upper benchset values can be imported into a single INtools field as 'minbenchrange'+' - '+'maxbenchrange' to import a bench set of '3 - 1.
Hexagon Process, Power & Marine"With SPO [Smart. Plant® Enterprise for Owner Operators] we are ordering all the information and we have all this information regarding the design tools in order so we are using all of the design tools to controlling the MOC, or management of change, in the plant, so every time that we have a change in the plan, we are reusing all of the engineering information from the project. Keeping alive all of these design tools was very useful. We are saving tons of time and money because of that."Patricio Soto. Information Manager, Caserones SCM Minera Lumina Copper.